Preparing for a commercial plumbing final

Requesting a final inspection

Preparing for a commercial final, the following requirements must be checked:

  • All fees relevant to the permit are to be paid.
  • A full set of electronic as-constructed drawings in the same format as the stamped approved plans, emailed to council@logan.qld.gov.au.
  • All permit conditions have been achieved.
  • Test and tag all new devices installed with QR2ID (where applicable).
  • Form 9 - Backflow Prevention Valve Test Report for each installed device.

As-constructed drawings

The as-constructed drawings shall be completed in the same format as the stamped approved plans and must include the following:

  • Plumbing application number (all pages)
  • Drainage plan number (all pages)
  • Street address (all pages)
  • Real property address, e.g. Lot, RP or SP number (front/cover page)
  • The words “AS CONSTRUCTED” (all pages)
  • Plumber’s details, licence and phone number
  • Shop number, tenant, business name and floor (all pages)
  • Master meter and sub water meter table completed with meter details where applicable (existing water meters may be exempt)
  • Testable Backflow Prevention device table completed where applicable.

Note: Council will not accept handwriting or written corrections on any plans.

Council’s Plumbing Inspectors require the following documents to be available electronically prior to booking the commercial final inspection:

  • A full set of marked-up stamped approved plans (to be on site).
  • A full set of as-constructed drawings of the same size as the stamped approved plans.
  • A copy of the following documents where applicable:
    • Form 71 – Fire service test report
    • Form 9 – Backflow Prevention Valve Test Report for each device
    • TMV report(s)
    • Proof of watermark product certification for approved products.

The plumbing contractor will not be able to book a commercial final plumbing inspection if the above documents have not been provided to Council’s Plumbing team. Additional fees may apply.

Plumbing inspections bookings: 07 3421 4840 (8:00am to 5:00pm)
Plumbing assessment email: council@logan.qld.gov.au

Examples

BACKFLOW PREVENTION TABLE DEVICE
MAKE TYPE LOCATION SIZE SERIAL No
WATTS RPZD FRONT ENTRY TENANCY 4 40 A02272
WATTS RPZD BIN STORE BEHIND TENANCY 4 20 A35083
VALVCHEQ DBCV MAIN DOOR NEXT TO TENANCY 3 50 10817720123
ZURN RPZD DOG WASH NEXT TO TENANCY 6 20 B269919
WATTS SCV NEXT TO MASTER METER 150 AN00006
 WATER METER TABLE
UNIT No TYPE SERIAL No LOCATION SIZE READING AT INSTALLATION READING AT COMPLETION
COMMUNAL STANDARD SK09-MI001-SMU008 AT FRONT BOUNDARY 150 0000001 0000167
TENANCY 1 STANDARD 000246 BOH TENANCY 1 20 00000 00001
TENANCY 2 STANDARD 000247 BOH TENANCY 2 20 00000 00001
TENANCY 3 STANDARD 000248 BOH TENANCY 3 20 00000 00001
TENANCY 4 STANDARD 24VE0003 BOH TENANCY 4 40 00000000 00000284
TENANCY 5 STANDARD 000249 BOH TENANCY 5 20 00000 00001
TENANCY 6 STANDARD 000250 BOH TENANCY 6 20 00000 00001
DOG WASH  STANDARD 004453 RIGHT HAND SIDE T6 25  00000 00001
 Pre-Treatment Table - Existing GA No. 2
Fixture Capacity (L) No. Of Total Capacity (L) Trap Size
FRESH PREP/COOLROOM 3000L
SINK - DOUBLE BOWL (<300 deep) 150 2 300
SINK - SINGLE BOWL (<300 deep) 75 1 75
HAND BASIN 50 3 150
FLOOR WASTE/BUCKET TRAP/GRATED STRIP DRAIN (50LPF 50m²) 50 2 100
Ex Roast Runner Ovens 150 1 150
TUNDISH (other) 3 4 12
FRUIT AND VEG PREP BOH
SINK - DOUBLE BOWL (<300 deep) 150 1 150
HAND BASIN 50 1 50
FLOOR WASTE/BUCKET TRAP/GRATED STRIP DRAIN (50LPF 50m²) 50 1 50
TUNDISH (other) 3 3 9
TRADING FLOOR
TUNDISH (other) 3 29 87
TOTAL 1133